McD RUSSIA New Store Checklist

6. General Standards

• Drawings match the McD/ Architects layout (LO) drawing (any issues are clouded/ flagged). □

• All H&K text shown horizontally where possible.

• Russian Colour Legend shown on all layouts.

• Use McDonalds existing equipment symbols on Remodels where the equipment is not moved. □

• K4 Elevations only shown for new or relocated equipment.

Show local items if one item relocated. E.g. Apple Pie relocated to existing bagging station

– Show the Apple Pie on the bagging station in K4.

• Do not show walls on K4.

• All stations need to be against walls, no air gaps between them.

• Missing walls due to LO inaccuracy to be shown in green hatching (new walls).

• Change any English text shown on LO drawings using the translation below.

Moneyroom/office

Офис

Storage

Склад

Locker Male

Мужская раздевалка

Locker Female

Женская раздевалка

Crew

Комната отдыха персонала

7.

Clearances

(Minimum distances for Remodels & New Stores)

• Working operator (crew) space

900mm

• Front counter to Menu Board Wall

1100mm – 1500mm

• OAT to Fry/ Filet/ Grill

1200-1300mm

• OAT to Front Counter/ Beverage Cell

1600mm – 2000mm

• Parallel Beverage Cell

1200mm

• Current BIC

Sides 150mm Back 50mm

(Manitowoc V1)

Top 460mm Front 760mm

• New BIC (TBC)

Top breathing (clearance TBC)

• Shakes M/C

Sides 76mm

• Upright Freezers/ Chillers

Sides 50mm / Rear 50mm

• Futures

Show Future sizes as 960W x 980D

• Multiplex

Minimum wall to wall clearance of 1900mm required.

• Any distance not matching the min. requirement must be “revclouded”.

Page | 7

Made with FlippingBook - Online catalogs