McD RUSSIA New Store Checklist
5. Dimensions & Callouts
• K1 Elevation callouts shown using numbers only.
□
• K1 Dimensions to be shown in all areas (width & depth for Buyouts or FAB).
□
• K1 Elevation callouts numbered clockwise from beverage cell.
□
• K1 Dimensions& Callouts shown on layer “DIMENSIONS”.
□
• K1 Dimensions shown to the front of all new equipment.
□
• K1 Dimension strings are in line.
□
• K1 All new equipment gaps are shown.
□
• K1 All dimensions are clear and unobstructed.
□
• K1 Dimensions shown from end of line equipment to nearest wall.
□
• K1 Dimensions are shown across any tight spaces/ niches.
□
• K1 Dimensions are shown on the front counter(s) and walkway.
□
• K1 Dimension is shown from the front counter to the opposite wall.
□
• K1 Clearance dimensions are shown to all walkways
.
□
• K1 MFY Line dimensions shown at front of OAT Table.
□
• K1 MFY Prepline to be centred as per McDonalds LO.
□
• K2 Dimensions & Callouts shown on layer “EQUIPMENT SERVICE”
□
• K2 Service callouts numbered clockwise from Beverage Cell.
□
• K2 2 x Dimensions shown from all floor traps to structural walls.
□
• K2 Dimensions shown from chases to nearest wall edge.
□
• K2 Dimensions shown from wall edge to each service point (use stacked dimensions).
□
• K2 Dimension string shown to hood edges and duct centres.
□
• K2 MFY & OAT chase dimensions shown to structural wall (not front counter).
□
• K2 Dimensions shown in multiples of 50mm where possible.
□
• K4 Elevation view numbers match K1 elevation callouts.
□
• K4 Dimension strings shown on plan view equipment.
□
• K4 Dimensions shown for relevant heights (counter-tops & shelves).
□
Page | 6